Power Factor Controller

iTopPlus752713810970    iTopPlus1481803380385    iTopPlus796882167754    iTopPlus1523070315775

The PFCevo automatic power factor control unit has been designed to offer state-of-the-art functions for power factor compensation applications. Built with dedicated components and extremely compact, the PFCevo combines the modern design of the front panel with practical installation and the possibility of expansion from the rear, where one expansion module can be slotted. The LCD screen provides a clear and intuitive interface to the user.

Documents

✚ PFC96evo - PFC144evo
✚ PFC96evo - PFC144evo Manual

Display indications


iTopPlus866270330890

TECHNICAL CHARACTERISTICS
Automatic power factor controller
Flush-mount, standard 96x96mm housing PFC96evo
Flush-mount, standard 144x144mm housing PFC144evo
Backlit LCD screen
PFC96evo with 5 relays, expandable to 7 max
PFC144evo with 8 relays, expandable to 12 max
4 navigation keys for function and settings
Alarm messages in 6 languages
Expansion bus modules:
   RS232, RS485, USB communications interface
   Additional relay outputs
High accuracy TRMS measurements
Wide selection of electrical measures, including voltage and current THD
with harmonic analysis up to 15th order
Voltage input separated from power supply, suitable for VT connection in
medium voltage applications
Wide-range power supply (100-440VAC)
Front optical programming interface: galvanically isolated, high speed,
waterproof, USB and WIFI dongle compatible
2-level password protection for settings
Backup copy of original commissioning settings
Built-in temperature sensor
Description
Supply
Rated voltage 100÷440 Vac 45÷66 Hz - 110÷250 Vdc
Power consumption/dissipation 2,5 W - 7,0 VA
Immunity time for microbreakings <25 mS
Voltage inputs
Maximum rated voltage 600 Vac - 45÷66 Hz
Measuring method True RMS
Wiring mode Single-phase, two-phase, three-phase with or
without neutral or balanced three-phase system
Current inputs
Rated current Ie Ie 1A or 5A
Measuring method True RMS
Overload capacity +20% Ie
Power consumption <0,6VA
Relay output: out 1-7
Contact type 7x1 NO + contact common
Rated current AC1-5A 250 Vac AC15-1,5A 440 Vac
Maximum current at contact common 10A
Relay output: out 8
Contact type 1 changeover
Rated current AC1-5A 250Vac AC15-1,5A 440Vac
Insulation voltage
Rated insulation voltage 600 Vac
Rated impulse withstand voltage Uimp 9,5 KV
Ambient operating conditions
Operating temperature -20°C +60°C
Storege temperature -30°C +80°C
Connections
Terminal type Plug-in / removable
Cable cross section (min...max) 0,2...2,5 mm2 (24÷12 AWG)
Housing
Version Flush mount
Material Polycarbonate
Degree of protection IP54 on front with gasket- IP20 terminals
Weight 640 g
Certification and compliance
Reference standards IEC/EN 61010-1, IEC/EN 61000-6-2
IEC/EN 61000-6-4 UL508 CSA C22.2-N°14